Multi-Contact Cables & Connectors
The Multi-Contact Solarline family of connectors delivers a
flexible system solution for time-saving, dependable series cabling of solar
modules. All module manufacturers supply their grid-tie modules with
pre-assembled output cables, tested and ready for connection. This saves
considerable time during an installation and greatly increases reliability over
wire junction boxes. These cable couplers are fully touch-protected and designed
for up to 1000 volts and 30 amps. They are also waterproof. For parallel
connection of modules in 12- to 48-volt systems, Multi-Contact makes branch
connectors for use with currents up to 30 amps.
MC3 Solarline 1 & MC4 Solarline 2
Array Output Cables Use them to extend module output cables or cut anywhere along the wire to obtain the needed length of male and female cable to run from the ends of a module string to a combiner box or to an inverter. For example, if you need a 30' male and a 20' female, order a 50' cable. Made with black #10 AWG USE-2 sunlight-resistant cable.
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
MC4
Solarline 2 Direct Burial PV-Wire Cables These cables have the newer, snap-together Multi-Contact hard plastic connectors on each end and are made with PV-Wire that has an extra layer of insulation for use on ungrounded arrays in conjunction with transformerless inverters. This type of wire is required to meet the 2008 NEC if you are using a transformerless inverter. |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
MC3 Solarline 1 & MC4 Solarline 2
Color-Coded Cables Use these output cables between PV arrays with Multi-Contact cable outputs, and junction boxes or grid-tie inverters. White cables have an MC connector that fits the module negative output cable. Red and black cables have an MC connector that fits the module positive output cable. Made from #10 AWG USE-2 sunlight resistant cable. |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
MC Solarline 1 & 2 Connectors
The connector can be assembled quickly on site by a contractor allowing
custom cables to be made at the job site. A special crimping tool and wrench set
are required to
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Industrial Operations (AIO) offers products and solutions for all segments of the solar electric system. AIO understands the need for efficient (low loss) power transfer, highly reliable, and cost effective solutions that are required to be competitive in this industry. Providing panel manufacturers, installers, and OEM's with connectivity products for both thin film and crystalline silicon technologies. has a broad range of technologies to help minimize the cost of inverters and power conditioners. Industrial can help you power the planet with the sun. The Helios H4 connector is just one of the solar connector solutions Industrial has to offer. These connector can be assembled quickly on site by a contractor allowing custom cables to be made at the job site. A special crimping tool and wrench set are required to assemble the connector. For 10 and 12 AWG USE-2 wire. Sold 25 pair per bag
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Tyco SolarLok Connectors The connector can be assembled quickly on site by a contractor allowing custom cables to be made at the job site. A special crimping tool and wrench set
are required to assemble the connector.
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
MultiContact 1 Branch Connectors![]()
These waterproof Y-connectors make it possible to parallel wire PV
modules with MultiContact output cables. Maximum current allowed through these
connectors is 30 amps.
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
MC Solarline 2 Branch Connectors![]() These waterproof Y-connectors make it possible to parallel wire PV modules with Multi-Contact output cables. Maximum current allowed through connectors is 30 amps.
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
MC Solarline 2 to Solarline 1 Connectors![]() Use these adapters to connect new style Solarline 2 modules to the Solarline 1 cables or anywhere a transition is needed between Solarline 1 and Solarline 2 cables.
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Cable Clip![]()
Use this clip to keep module interconnect cables neatly connected to module
frames so they do not
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Waterproof
Strain ReliefsUse the 1/2" threaded connectors to provide a waterproof entrance or exit for wiring on PV module junction boxes, outdoor combiner boxes, and junction boxes. Use the 3/4" connector for larger cables up to 5/8" diameter. They are made of Nylon with Buna-N seals and are resistant to salt water, weak acids, weak alkalis, alcohol, ether, esters, ketones, and mineral, animal and vegetable oils. The threads are 1/2" or 3/4" NPT. Non-corrosive and suitable for direct burial installations. The oval-hole 1/2" strain relief works great for two-conductor TC cable used for module interconnects and for PV outputs or for UF cable. The two-hole 1/2" connector is designed for use with two #10 or #12 type USE conductors like the ones used for Multi-Contact PV output cables. UL Listed. Suitable for use in NEMA 4, 6 and 12 applications.
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Direct
Burial/Sunlight Resistant Cable![]() Type USE single-conductor copper wire for lead-in from PV arrays, wind and hydroelectric systems. May be used for AC or DC wiring up to 600 volts. |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
PV Wire Sunlight
Resistant Cable
This single conductor insulated with heat and moisture resistant, cross-linked polyethylene insulation, (Type USE-2), with an overall flame and sunlight resistant, Zero Halogen, Limited Smoke, Zero lead jacket meets the 2008 NEC code for use with transformerless inverters. UL Listed as Type PV Cable Conductors UL854 (#16 per UL 66) ICEA S-95-658/NEMA WC-70. |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|