AEI 12 Circuit Combiner Box![]() This PV Array Combiner Box, is designed to combine the output of up to 12 (PV) source circuits. It has 12 circuits in two banks for 6 fused inputs and a positive and negative output for each bank. This allows the division of a large array into two wire pairs that can be connected to two charge controls. It is like having two combiners in one NEMA 3R lockable enclosure. Each circuit can accept up to 15 Amps of PV input current up to a total maximum of 120 Amps. It may be used with 12, 24 and 48 VDC PV systems. Made by Beacon
|
||||||||||||||||||||||||||||||||||||
|
Type ABC Fuses for Combiner Boxes These fuses can be used with the Xantrex, Connect and AEI Combiner boxes. Use a fuse equal to or less than the series fuse rating of the modules being protected.
|
||||||||||||||||||||||||||||||||||||
DC Ground Fault Protection![]() These specially designed Xantrex circuit breakers meet the NEC requirement for Ground Fault Protection of PV arrays mounted on roofs of dwellings. Each pole can carry up to 100 amps for arrays up to 100 VDC open circuit. UL listed.
The GFP enclosure is specially designed to house the Xantrex ground fault protectors (see above) and is white powder-coated. It can also be used with up to 5 CD type DC (lug type) circuit breakers with the optional mounting plate.
TOP |
||||||||||||||||||||||||||||||||||||
Connect PCB10 Combiner Box![]() The Connect Energy’s PV Array Combiner Box, PCB10, is designed to combine the output of multiple solar electric (PV) source circuits. The PCB10 has 10 fused circuits in a NEMA 3R lockable enclosure. Each circuit can accept up to 15 Amps of PV input current up to a total maximum of 64 Amps. The PCB10 may be used with 12, 24 and 48 VDC PV systems and can handle a maximum 125 VDC input and includes built-in lightning protection. protection. UL listed. Use Type ABC Fuses. Dimensions are 8"W x 10"H x 4"D.
|
||||||||||||||||||||||||||||||||||||
PACS-2 Unfused Combiner![]() This unfused array combiner allows connection of up to eight positive and eight negative #10 AWG wires to output cables of up to 2/0 AWG. This is useful for connecting array wiring to larger wire that runs from a roof or pole mount to a power system center. Includes a Delta 300 VDC lightning arrestor and grounding terminal. NEMA 3R rain tight encolsure.
|
||||||||||||||||||||||||||||||||||||
OutBack PSPV Array Combiner Box
![]() The PSPV outdoor, rainproof powder-coated aluminum array combiner can be used with a wide variety of PV system designs and module configurations. It can be installed on vertical or sloped surfaces (14-90 degrees from horizontal) or pole mounted and configured with DC breakers for low voltage systems (under 140 VDC) or touch safe type fuse holders for high voltage systems (up to 600 VDC). The PSPV is designed to provide NEC code compliant overcurrent protection and interconnection of multiple PV panels or subarrays into one or more PV arrays for connection to charge controllers or inverter systems. The PSPV is easily field configured to match your system design and ampacity requirements. It is shipped without the breakers or fuse holders installed. Order the quantity, type and amperage needed. Snap in DIN rail mounting system has spaces for up to twelve DC rated PV breakers for 12, 24, 48 and 60 VDC PV arrays with open circuit voltages up to 140 VDC, or up to seven touch safe type midget fuse holders for high voltage PV arrays up to 600 VDC. Dual positive breaker combiner busbars with #1/0 AWG set-screw compression type box lug terminals for output wiring provide one or two PV output circuits. There is one PV negative terminal bus bar with mounting holes for an additional bus bar. Wire access is through four ¾ and 1 inch conduit knockouts, one on the bottom, back and each side. Ample space provided on bottom and back to allow up to a 2 inch conduit punch for large cabling. Eight ½ inch knockouts on bottom for PV module or subarray input conduits or strain reliefs. A #1/0 AWG ground lug can be mounted either on the inside or outside surface. ETL Listed. NEMA 3R. Dimensions:13.1"H x 9.2"W x 3.5"D. |
||||||||||||||||||||||||||||||||||||
OutBack PSSB 600 VDC Array Disconnect
![]() PSSB is a PV array disconnect designed specifically to work with the SMA Sunny Boy line-tie inverter systems. It can also be used with other high voltage utility interactive PV inverters or other applications such as large inverter power systems or water pumping systems. It can also be used as a standard 600 VDC disconnect for a single high voltage PV array. The PSSB is designed to provide NEC code compliant overcurrent protection and disconnect means of up to six separate low voltage PV subarrays to form a single high voltage PV array for connection to a high voltage PV inverter. An optional AC breaker disconnect can also be field installed inside the same enclosure to provide a local means of disconnect at the location of the inverter. Or add a second 6-pole breaker. Outdoor, rainproof powder coated aluminum enclosure can be installed on vertical or sloped surfaces down to a 3/12 pitch (14 degrees). For subarrays of 48 vdc nominal with an open circuit of less than 100 vdc maximum. ETL Listed. NEMA 3R. Dimensions:13.1"H x 9.2"W x 3.5"D. |
||||||||||||||||||||||||||||||||||||
|