Wiley Electronics – WEEB Grounding Products WEEB stands for “washer, electrical equipment bonding”
The WEEB family of products are used to bond solar modules to
aluminum solar mounting rails. The mounts are then grounded so the entire
assembly is grounded. This eliminates the need to use a |
|||||||||||||||||||||||||||||||||||
![]() The WEEB-9.5 is used for bonding modules to mounting structures when the modules are directly bolted to the rails using 1/4" bolts through the mounting holes on the rear of the module frames. This type of mounting is typical on DP&W ground and pole mount systems (pages 42-48) and on Wattsun and Zomeworks trackers (49-51). The WEEB-9.5NL is used for bonding strong-back structure and legs to the rail where 3/8" bolts are used. Sold in packs of 100. |
|||||||||||||||||||||||||||||||||||
|
|
|||||||||||||||||||||||||||||||||||
WEEB-UMC
grounding
clips are used between modules and UniRac SolarMount Standard Rails or
SolarMount Light Rails when front mount clips are used to hold the module to
the rails.One clip grounds the frame of 2 adjoining modules to one of the mounting rails. Two clips are required for each pair of modules so that the modules will be bonded to both rails. Sold in packs of 100. |
|||||||||||||||||||||||||||||||||||
|
|
|||||||||||||||||||||||||||||||||||
WEEB-PMC grounding clips
are used between modules and ProSolar rails when front mount clips are used
to hold the module to the rails.
One clip grounds the frame of 2 adjoining modules to one of the mounting rails. Two clips are required for each pair of modules so that the modules will be bonded to both rails. Sold in packs of 100. |
|||||||||||||||||||||||||||||||||||
|
|
|||||||||||||||||||||||||||||||||||
The
WEEB L-6.7
provides a connection to the mounting system and has lay-in provision
for an equipment ground conductor. The WEEB-6.7 kit includes the lay-in lug,
matching WEEB washer, bolt, nut flat washer and lock washer.
Two WEEB lugs and a short piece of bare wire can be used to connect across a rail splice, or a WEEB splice kit can be used. Sold in packs of 10. |
|||||||||||||||||||||||||||||||||||
|
|
|||||||||||||||||||||||||||||||||||
WEEB splice kit
is used to bond two rails
together at a splice.Sold in packs of 5. |
|||||||||||||||||||||||||||||||||||
|
|
|||||||||||||||||||||||||||||||||||
Lay-in Lugs for Module Grounding![]() These tin plated copper lugs have stainless steel set screws and come with stainless steel thread-forming screws and lock washers, to meet NEC requirements for connecting a continuous ground wire to all modules in an array and having the ability to remove a module without breaking grounding continuity for the rest of the aray.
Sold in packages of 10 with
thread-forming screws.
|
|||||||||||||||||||||||||||||||||||
|
|
|||||||||||||||||||||||||||||||||||
|
Grounding Rods 8
foot by 5/8 inch in diameter copper clad grounding rods |
|||||||||||||||||||||||||||||||||||
|
|
|||||||||||||||||||||||||||||||||||
Xantrex DC Ground Fault Protection![]() These specially designed Xantrex circuit breakers meet the NEC requirement for Ground Fault Protection of PV arrays mounted on roofs of dwellings. Each pole can carry up to 100 amps for arrays up to 100 VDC open circuit. UL listed. The GFP enclosure is specially designed to house the Xantrex ground fault protectors (see above) and is white powder-coated. It can also be used with up to 5 CD type DC (lug type) circuit breakers with the optional mounting plate.
|
|||||||||||||||||||||||||||||||||||
|
|
|||||||||||||||||||||||||||||||||||
|
All transactions made on
this site are secure and Hacker Safe. All Our Payments are processed
through PayPal, a trusted company owned and operated by eBay.com |
|||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||